Executed a Reliability Availability Maintainability (RAM) Study for the Parkland Strategic Project Renewable Fuels Unit (RFU) and Hydrogen Unit (HU) units to determine he Production Availability of the combined RFU and HU plants to process 6,500 BPSD of bio-feed to produce renewable diesel and up to 40% Sustainable Aviation Fuel (SAF). Computational Fluid Dynamics (CFD) to assess water accumulation in the CVG Line and sediment settling in the emulsion Line, corrosion simulation, topography mapping, risk assessment, and design modifications.